| Component - Plastics | E329660 | |
| SHENZHEN TEESUN TECHNOLOGY CO LTD | ||
| Blk 5 Sha-Pu-Wei-Mao-Zhou Ind Zone, Songgang Town, Baoan District, Shenzhen Guangdong 518105 CN | ||
| TS-FR1365, TS-FR1363, TS-FR1360, TS-FR1362, TS-FR160Y, TS-FR1370F, TS-FR1370, TS-FR1383, TS-FR1370-32, TS-FR1383-13 | ||
| Polycarbonate (PC), furnished as sheet or roll | ||
| Min Thk | Flame | RTI | RTI | RTI | |||
| Color | (mm) | Class | HWI | HAI | Elec | Imp | Str |
| NC, BK | 0.05 - 0.199 | VTM-0 | 2 | - | 80 | 80 | 80 |
| 0.20 - 0.22 | VTM-0 | 2 | - | 130 | 125 | 130 | |
| 0.25 - 1.65 | V-0 | 0 | - | 130 | 125 | 130 |
| Comparative Tracking Index (CTI): | - | Inclined Plane Tracking (IPT): | - |
| Dielectric Strength (kV/mm): | - | Volume Resistivity (10x ohm-cm): | - |
| High-Voltage Arc Tracking Rate (HVTR): | 4 | High Volt, Low Current Arc Resis (D495): | 6 |
| Dimensional Stability (%): | - |
| ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. |
|
Report Date:
2012-05-25 Last Revised: 2015-05-21 |
© 2015 UL LLC |
| IEC and ISO Test Methods | ||||
| Test Name | Test Method | Units | Thk (mm) | Value |
| Flammability | ISO 9773, IEC 60695-11-10 | Class (color) | 0.05 - 0.199 | VTM-0 (NC, BK) |
| 0.20 - 0.22 | VTM-0 (NC, BK) | |||
| 0.25 - 1.65 | V-0 (NC, BK) | |||
| Glow-Wire Flammability (GWFI) | IEC 60695-2-12 | C | - | - |
| Glow-Wire Ignition (GWIT) | IEC 60695-2-13 | C | - | - |
| IEC Comparative Tracking Index | IEC 60112 | Volts (Max) | - | - |
| IEC Ball Pressure | IEC 60695-10-2 | C | - | - |
| ISO Heat Deflection (1.80 MPa) | ISO 75-2 | C | - | - |
| ISO Tensile Strength | ISO 527-2 | MPa | - | - |
| ISO Flexural Strength | ISO 178 | MPa | - | - |
| ISO Tensile Impact | ISO 8256 | kJ/m2 | - | - |
| ISO Izod Impact | ISO 180 | kJ/m2 | - | - |
| ISO Charpy Impact | ISO 179-2 | kJ/m2 | - | - |