| Component - Plastics | E39437 | |
| ARKEMA INC | ||
| 900 1ST AVE, KING OF PRUSSIA PA 19406-1308 | ||
| G#(f2) | ||
| Polymethyl Methacrylate (PMMA), "Plexiglas, Altuglas", furnished as sheets | ||
| Min Thk | Flame | RTI | RTI | RTI | |||
| Color | (mm) | Class | HWI | HAI | Elec | Imp | Str |
| ALL | 1.5 | HB | 4 | 0 | 90 | 90 | 90 |
| 3.0 | HB | 4 | 0 | 90 | 90 | 90 |
| Comparative Tracking Index (CTI): | - | Inclined Plane Tracking (IPT): | - |
| Dielectric Strength (kV/mm): | - | Volume Resistivity (10x ohm-cm): | - |
| High-Voltage Arc Tracking Rate (HVTR): | - | High Volt, Low Current Arc Resis (D495): | - |
| Dimensional Stability (%): | - |
| # - | May be followed by letters M or F. |
| (f2) - | Subjected to one or more of the following tests: Ultraviolet Light, Water Exposure or Immersion in accordance with UL 746C, where the acceptability for outdoor use is to be determined by UL. |
| NOTE - | Grade designations may be followed by letters and/or numbers indicating color. |
| ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. |
|
Report Date:
1989-02-13 Last Revised: 2014-12-05 |
© 2015 UL LLC |
| IEC and ISO Test Methods | ||||
| Test Name | Test Method | Units | Thk (mm) | Value |
| Flammability | IEC 60695-11-10 | Class (color) | 1.5 | HB75 (ALL) |
| 3.0 | HB40 (ALL) | |||
| Glow-Wire Flammability (GWFI) | IEC 60695-2-12 | C | - | - |
| Glow-Wire Ignition (GWIT) | IEC 60695-2-13 | C | - | - |
| IEC Comparative Tracking Index | IEC 60112 | Volts (Max) | - | - |
| IEC Ball Pressure | IEC 60695-10-2 | C | - | - |
| ISO Heat Deflection (1.80 MPa) | ISO 75-2 | C | - | - |
| ISO Tensile Strength | ISO 527-2 | MPa | - | - |
| ISO Flexural Strength | ISO 178 | MPa | - | - |
| ISO Tensile Impact | ISO 8256 | kJ/m2 | - | - |
| ISO Izod Impact | ISO 180 | kJ/m2 | - | - |