Component - Plastics | E86172 | |
E I DUPONT DE NEMOURS AND COMPANY | ||
1007 N MARKET ST, WILMINGTON DE 19898-1101 | ||
TUT20BG3 | ||
Polyvinyl Fluoride (PVF), "TEDLAR" |
Min Thk | Flame | RTI | RTI | RTI | |||
Color | (mm) | Class | HWI | HAI | Elec | Imp | Str |
TP | 0.051-0.056 | HB | - | - | 140 | 120 | 125 |
Comparative Tracking Index (CTI): | - | Inclined Plane Tracking (IPT): | - |
Dielectric Strength (kV/mm): | - | Volume Resistivity (10x ohm-cm): | - |
High-Voltage Arc Tracking Rate (HVTR): | - | High Volt, Low Current Arc Resis (D495): | - |
Dimensional Stability (%): | - |
NOTE - | Tedlar is a registered trademark of DuPont |
ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. |
Report Date:
1984-10-26 Last Revised: 2006-11-15 |
© 2015 UL LLC |
![]() |
IEC and ISO Test Methods | ||||
Test Name | Test Method | Units | Thk (mm) | Value |
Flammability | IEC 60695-11-10 | Class (color) | 0.051-0.056 | HB75 (TP) |
Glow-Wire Flammability (GWFI) | IEC 60695-2-12 | C | - | - |
Glow-Wire Ignition (GWIT) | IEC 60695-2-13 | C | - | - |
IEC Comparative Tracking Index | IEC 60112 | Volts (Max) | - | - |
IEC Ball Pressure | IEC 60695-10-2 | C | - | - |
ISO Heat Deflection (1.80 MPa) | ISO 75-2 | C | - | - |
ISO Tensile Strength | ISO 527-2 | MPa | - | - |
ISO Flexural Strength | ISO 178 | MPa | - | - |
ISO Tensile Impact | ISO 8256 | kJ/m2 | - | - |
ISO Izod Impact | ISO 180 | kJ/m2 | - | - |
ISO Charpy Impact | ISO 179-2 | kJ/m2 | - | - |